Deltopectoral or Anterosuperior Approachin Total Reverse Shoulder Arthroplasty:Differences in Metaglene Positioning

Authors

Keywords:

Arthroplasty, Replacement, Shoulder, Shoulder Joint, Shoulder Prosthesis

Abstract

Introduction: Our purpose was to evaluate the differences in metaglene positioning in deltopectoral and anterosuperior approach in total reverse shoulder arthroplasty.
Methods: Patients who underwent total reverse shoulder arthroplasty for degenerative or traumatic pathology within a 10‐year period were selected. Two groups were created: group 1, deltopectoral approach; group 2, anterosuperior approach. The metaglene positioning was evaluated through anteroposterior radiography by the methods of Lévigne et al and Maurer et al. Statistical study was performed by Mann‐Whitney U‐test.
Results: A total of 145 patients were admitted, 33 submited to deltopectoral approach and 112 anterosuperior. Surgery for degenerative pathology occurred in 106, for trauma in 39. The overall median age was 70 years (64‐75), in degenerative pathology 68 years (62‐72), in trauma 76 years (69‐81). Overhang showed no significant difference (p=0.882), 5.1±2.2 mm group 1 and 5.4±2 mm group 2. The tilt showed significant difference (p=0.005), 103.2±11o group 1 and 96.8±9.7o group 2. The beta angle showed significant difference (p=0.001), 81.4±7.3o group 1 and 74.6±8.6o group 2. When comparing traumatic and degenerative pathology, the overhang did not show significant difference (p=0.06), 5.8±1.6 mm traumatic pathology and 5.1±2.2 mm degenerative pathology. The tilt was signifi‐ cantly different (p<0.001), 104.8±10° traumatic pathology and 95.8±9.4o degenerative pathology. The beta angle was significantly different (zc wq <0.001), 82.5±6.6o traumatic pathology and 73.8±8.4o degenerative pathology.
Conclusion: The approaches did not differ in the craniocaudal positioning of the metaglene, but tilt was lower in the anterosuperior approach and may correlate with future complications. Patients who had surgery for traumatic pathology showed greater inferior tilt of the metaglene.

Downloads

Download data is not yet available.

References

Thon SG, Seidl AJ, Bravman JT, McCarty EC, Savoie FH, Frank RM. Advances and Update on Reverse Total Shoulder Arthroplasty. Curr Rev Musculoskelet Med. 2020;13:11‐9. doi:10.1007/s12178‐019‐09582‐2

Simovitch R, Flurin PH, Wright TW, Zuckerman JD, Roche C. Impact of scapular notching on reverse total shoulder arthroplasty midterm outcomes: 5‐year minimum follow‐up. J Shoulder Elbow Surg. 2019;28:2301‐7. doi:10.1016/j.jse.2019.04.042

Schrumpf M, Maak T, Hammoud S, Craig EV. The glenoid in total shoulder arthroplasty. Curr Rev Musculoskelet Med. 2011;4:191‐9. doi:10.1007/s12178‐011‐9096‐5

Lévigne C, Boileau P, Favard L, Garaud P, Molé D, Sirveaux F, et al. Scapular notching in reverse shoulder arthroplasty. J Shoulder Elbow Surg. 2008;17:925‐35. doi:10.1016/j.jse.2008.02.010

Torrens C, Amestoy J, Rodríguez‐Delourme I, Santana F. Positioning of the metaglene in reverse shoulder arthroplasty: deltopectoral versus anterosuperior approach: a prospective randomized trial. J Shoulder Elbow Surg. 2021;30:2682‐90. doi:10.1016/j.jse.2021.07.025

Koh J, Galvin JW, Sing DC, Curry EJ, Li X. Thirty‐day complications and readmission rates in elderly patients after shoulder arthroplasty. J Am Acad Orthop Surg Glob Res Rev. 2018;2:e068. . doi:10.5435/ JAAOSGlobal‐D‐18‐00068

Bacle G, Nove‐Josserand L, Garaud P, Walch G. Long‐term outco‐ mes of reverse total shoulder arthroplasty: A follow‐up of a previous study. J Bone Joint Surg Am. 2017;99:454‐61. doi: 10.2106/ JBJS.16.00223. PMID: 28291177.

Vanhove B, Beugnies A. Grammont’s reverse shoulder prosthesis for rotator cuff arthropathy.A retrospective study of 32 cases. Acta Orthop Belg. 2004;70:219‐25.

Sirveaux F, Favard L, Oudet D, Huquet D, Walch G, Molé D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388‐95. doi: 1.1302/0301‐620x.86b3.14024.

Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C. Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am. 2007;89:588‐600. doi: 10.2106/JBJS.F.00226.

Maurer A, Fucentese SF, Pfirrmann CW, Wirth SH, Djahangiri A, Jost B, et al. Assessment of glenoid inclination on routine clinical radiogra‐ phs and computed tomography examinations of the shoulder. J Shoulder Elbow Surg. 2012;21:1096‐103. doi:10.1016/j.jse.2011.07.010

de Wilde LF, Poncet D, Middernacht B, Ekelund A. Prosthetic overhang is the most effective way to prevent scapular conflict in a reverse total shoulder prosthesis. Acta Orthop. 2010;81:719‐26. doi:10.3109/17 453674.2010.538354

Gutiérrez S, Greiwe RM, Frankle MA, Siegal S, Lee WE. Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesis. J Shoulder Elbow Surg. 2007;16:S9‐S12. doi: 10.1016/j.jse.2005.11.008.

Laver L, Garrigues GE. Avoiding superior tilt in reverse shoulder arthroplasty: A review of the literature and technical recommendations. J Shoulder Elbow Surg. 2014;23:1582‐90. doi:10.1016/j. jse.2014.06.029

Nyffeler RW, Werner CML, Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg. 2005;14:524‐8. doi:10.1016/j. jse.2004.09.010

Werner CML, Steinmann PA, Gilbart M, Gerber C. Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse‐ball‐and‐socket total shoulder prosthesis. J Bone Joint Surg Am. 2005;87:1476‐86. doi: 10.2106/JBJS.D.02342.

Published

2024-01-21

Data Availability Statement

The full set of data is available in the attached document. Participants' consent was not obtained, but the data presented is anonymised and the risk of identification is reduced.

Issue

Section

Original Article

How to Cite

Deltopectoral or Anterosuperior Approachin Total Reverse Shoulder Arthroplasty:Differences in Metaglene Positioning. (2024). Orthopaedic SPOT, 1(1), 17-23. https://orthopaedicspot.com/index.php/journal/article/view/6

Most read articles by the same author(s)

1 2 > >> 

Similar Articles

You may also start an advanced similarity search for this article.